The flowmeter is ideally suited for applications in process. Data sheet electromagnetic flowmeter magmaster water. Datasheet for reciflow gas flow meter ec instruments. The hall effect sensor will then output a pulse width. Germany electromagnetic flowmeter picomag for utilities e. The highly costeffective flowmeter, available as compact wafer. Our product finder helps you to search for suitable measuring devices, software or system components via product characteristics. Fpr302303304 low flow polypropylene and tfe liquid. Promag measuring devices offer you costeffective flow measurement with a high degree of.
You can choose among various measuring principles electromagnetic measuring of volume flow, mass flow based on either the coriolis or thermal principle, measuring of volume flow based on the vortex or ultrasonic principle. The pulse output is normally used for totalization. We offer you the benefit of the d flow ufo asic, the d flow ultrasonic transducers and our knowhow. The kytola variable area flow meter model l is a sturdy. Flow is the process variable most frequently measured in industry. Insertion flow meter series 454ftbwgf technical specifications kurz instruments is dedicated to manufacturing and marketing the best thermal mass flow meters available and to support our customers in their efforts to improve their businesses.
Flow measurement of liquids in water or wastewater applications. Submersible sensor suitable for flooded chambers and pits buriable sensor. The 34 flow meter provides the user with extremely reliable readings for flow rates. St51 mass flow meter installation and operation guide. H coriolismaster fcb330, fcb350, fch330, fch350 change from one to two columns general data device description the coriolismaster fcb330, fcb350, fch330, fch350 is the most costeffective and least complex abb mass flowmeter. The optional 11 digit, twoline integral lcd display can be configured to alternate between selected display options e. Lngmass is a coriolis flowmeter specifically developed for dispensers. The first thermal mass flow meter offering accurate and reliable condensing gas flow. In the following text the term meter covers the heat meter as well as the cold meter and the flow sensor if not mentioned otherwise. Prowirl f is the multivariable flowmeter with inline wet steam measurement. Insertion flow meter series 454ftbwgf kurz instruments. For measuring the volume flow of liquids, gases and steam up to 250 bar and 450 c reliably. The flowmeter with integrated web server and a sensor with en iso 12944 corrosion protection. It provides isolated 4 to 20 ma and pulse outputs for flow rate, and a 4 to 20 ma output for process gas temperature.
Promag 50 transmitter promag d, promag l, promag w, promag p or promag h sensor in the compact version, the transmitter and sensor form a single mechanical unit. With genuine looppowered technology, prowirl f 200 enables costeffective and seamless integration into existing. Proline 300500 coriolis and electromagnetic flowmeters. Reference manual 0080901004662, rev da june 2011 rosemount 8732. B ambient temperature range 2024c and pressure range 9501050 mbar absolute. This flow meter requires specific timing and calculations to provide meaningful data, all of which is described in this datasheet. The deltabar transmitter is a reliable solution in the process industry. Flow measurement for liquids, gases and steam product overview for applications in liquids, gases and steam consistent product quality, safety, process optimization and environmental protection these are only a few reasons why industrial flow measurement is becoming more important all the time. The flow measuring system consists of the following components. Flow meter switch indicator omnihd2k 0420 ma or 0210 v output signal 2 x programmable switches pushpull backlit graphical lcd display transreflective, can be read in sunlight and in the dark programmable parameters via rotatable, removable ring programming protection all metal housing with scratch and chemical resistant. Technical information proline promag 10w electromagnetic flow measuring system flow measurement of liquids in water or wastewater applications application electromagnetic flowmeter for bidirectional.
The flowsic600 measurement device is an ultrasonic gas flow meter and sets the standard in its market segment for custody transfer of natural gas as well as steam flow measurement. This product line is especially suited for oem volume applications requiring small sized components with high performance at low cost. In the electromagnetic measuring principle, the flowing medium is the moving conductor. Automatic creation of the order code and its breakdown in pdf or excel output format. Where straight run limitations significantly reduce the available pipe diamet ers, fci. Introducing proline 300500, a family of industry optimized smart coriolis mass and electromagnetic flow instruments that simplify installation, speed commissioning, and streamline both operation and maintenance activities. The output signal of the model 515 is a sinusoidal frequency capable of driving a selfpowered flowmeter. This introductory course will start by providing maintenance and engineering personnel with a basic understanding of wiring, signals, instrumentation technologies. Product data sheet january 2014 0081004727, rev ue industry leading performance with standard reference accuracy of 0.
When liquid flows through the sensor, a magnetic rotor will rotate and the rate of rotation will vary with the rate of flow. St51 mass flow meter installation and operation guide recommended straight run to optimize flow meter system performance, fci recommends installation with a minimum of 20 pipe diameters upstream straight ru n and 10 pipe diameters of downstream straight run. The flowmeter with premium accuracy, robustness and extended transmitter functionality. It is used for flow measurements in water or service water applications. Volume flow measurement for standard applications with drinking water, wastewater. The t10 water meter consists of three major assemblies. The display is also used in conjunction with the configuration panel to access flow meter settings, such as 420ma and pulse output scaling, pipe diameter, zero flow cutoff, flow filtering damping, display options, and high or low alarm limits. Strict compliance with the instructions in the operating manual is mandatory. Water, natural gas, steam, mineral oil, chemicals or wastewater are only some examples of uids that have to be measured day in, day out. The 14 flow meter provides the user with extremely reliable readings for flow rates. Promag d, available as wafer version, is designed for all applications where space is at a minimum. D flow has the technology for ultrasonic flow measurement. Technical information proline promass 80e, 83e coriolis flowmeter minimized total cost of ownership and a compactremote transmitter application.
Signet 515 rotorx paddlewheel flow sensors simple to install with timehonored reliable performance, signet 515 rotorx paddlewheel flow sensors are highly repeatable, rugged sensors that offer exceptional value with little or no maintenance. End customers, skid builders, equipment manufacturers and system integrators value the spacesaving picomag for its flexible installation capabilities. Integral mount or remote mount magnetic flowmeter system notice read. The sensor with degree of protection ip68 type 6p enclosure and a modular electronic concept. Do not pick up by the electronic unit be careful of sharp edges thread, flange, measuring tube.
Energysaving flow measurement no pressure loss due to. The lg16 liquid flow meter series enables fast, noninvasive measurements of very low liquid flow rates below 5 mlmin. Our concept works just as well for standalone flow meters as for integration of flow functionality in a single product, an excellent way to cut costs for multiple interconnected systems. It is usually used at the inlet end to detect the amount of flow.
Differential pressure measurement for level, volume or mass measurement in liquids. This flow meter requires specific timing and calculations to provide meaningful data. The flowmeter with an integrated web server and weightoptimized sensor. The specialist in the water and wastewater industry for the most demanding applications. The yfs201 water flow sensor consists of a plastic valve body, flow rotor and hall effect sensor. Coriolismaster fcb330, fcb350, fch330, fch350 coriolis mass flowmeter 6 dsfcb300fch300en rev. The visually technical design demonstrates that it is geared to the tough industry conditions. The device meets all the specifications of the foundation fieldbus h1. Applicator leads you through an individual product selection via application parameters. The prosonic flow 92f is a calibrated meter capable of. A highest as volumetric flow rate, lowest as normalized. The 6 to 24 vdc pulse output of these meters is compatible with many different types of control, including a full range of omega rate displays and controls. For reading convenience, the register can be mounted in one of four positions on the meter. Excellent chemical resistance and biocompatibility are ensured.
Picomag is an electromagnetic flowmeter for bidirectional measurement of conductive liquids. Mass flow causes deceleration of the oscillation at the inlet of the tubes 2 and acceleration at the outlet 3. The meter is designed for circulating water of heating systems not for drinking water. Highest measurement performance for liquids and gases under varying, demanding process conditions. Flow pulse yifa the plastics ltd prodcut introduction 100lh. The fpr300 series comprises versatile impeller flow meters in 38 to 1 nominal pipe size that employ jewel bearings for very low minimum flows. Its calibration option premiumcal guarantees excellent measuring accuracy and highest plant availability at low flow rates of gas, steam and liquids. The t10 meter is available with a variety of register types. Electronic data sheet eds integrated in the measuring device. Available with hart, foundation fieldbus, or profibus pa, device diagnostics, and smart meter verification. Diagnostics and fault conditions, when present, will also appear on the.
1323 943 1130 434 89 271 1235 287 1141 565 1088 41 1484 1393 130 555 356 1383 794 110 87 856 303 513 505 323 996 305 314 52 568 1570 19 681 47 993 657 951 315 4 949 336 353 1054 1219